Cảm biến khoảng cách laser Sick OD1-B035H15I25
Measuring range
20 mm … 50 mm
Target
Natural objects
Repeatability
6 µm 1) 2)
Linearity
± 30 µm 3)
Response time
≥ 2 ms 4)
Output time
≥ 0.5 ms
Light source
Laser, red
visible red light
Type of light
Visible red light
Laser class
1 (IEC 60825-1:2014, EN 60825-1:2014) 5)
Typ. light spot size (distance)
800 µm x 450 µm (35 mm)
Additional function
Averaging 1 … 512x
Automatic or manual sensitivity adjustment
Analog outputs can be taught in
Digital outputs can be taught in
Invertable digital output
Switching mode: window (Wnd)
Switching mode: distance to object (DtO)
Switiching mode: object between sensor and background (ObSB)
Multifunctional input: laser-off / external teach-in / trigger
General notes
Note
Not free of paint wetting impairment substances.
Safety-related parameters
MTTFD
101 years
DCavg
0%
1) Averaging function set to: 512.
2) Constant ambient conditions.
3) Measurement on 90 % remission (ceramic, white).
4) With fixed sensitivity adjustment and averaging setting = 1. With automatic sensitivity and measuring rate 500 µs: 2 … 7.5 ms response time/measuring rate 1,000 µs: 4 … 15 ms response time.
5) Wavelength: 655 nm, max. output: 390 µW (laser class 1) / < 1 mW (laser class 2).
Technical drawings
Dimensional drawing Stainless steel housing
Connection type
connection diagram
Adjustments
Light spot size OD Mini Prime 20 mm … 50 mm
Linearity