Cảm biến khoảng cách laser Sick DL100-21AA2102
Measuring range
0.15 m … 100 m, on “diamond grade” reflective tape
Scope
Indoor
Target
Reflector
Resolution
0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm
Repeatability
0.5 mm 1)
Measurement accuracy
± 2 mm 2)
Response time
2 ms
Measurement cycle time
1 ms
Output time
1 ms
Light source
Laser, red 3)
visible red light
Type of light
Visible red light
Laser class
2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance)
5 mm + (2 mm x distance in m)
Max. movement speed
15 m/s
Acceleration (max.)
≤ 15 m/s²
Safety-related parameters
MTTFD
101 years
DCavg
0%
1) Statistical error 1 σ, environmental conditions constant, min. warm-up time 10 min.
2) From 150 mm … 180 mm measuring range the accuracy can reach ± 4 mm.
3) Average service life: 100,000 h at TU = +25 °C.
Technical drawings
Dimensional drawing
PROFIBUS IN connection type
PROFIBUS OUT connection type
Voltage supply connection type
PROFIBUS IN connection diagram
PROFIBUS OUT connection diagram
Voltage supply connection diagram
Ethernet connection diagram
Adjustment possible DL100-xxXXxx02