Cảm biến khoảng cách laser Sick DT20-N224B
Measuring range
100 mm … 1,000 mm 1)
Target
Natural objects
Repeatability
≥ 2.5 mm 1) 2) 3) 4)
Linearity
± 6 mm 3) 4) 5)
Response time
≥ 2.5 ms 2)
Output time
≥ 2.5 ms
Light source
Laser, red
visible red light
Type of light
Visible red light
Laser class
2 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance)
6 mm x 12 mm (1000 mm)
Additional function
Set moving average fast/medium/slow
Switching mode: distance to object (DtO)
Teach-in of digital output
Invertable digital output
Teach-in of analog output
Invertable analog output
Multifunctional input: laser off / external teach-in / deactivated
Switch-off display
Lock user interface
Safety-related parameters
MTTFD
101 years
DCavg
0%
1) 6% … 90% remission factor.
2) Dependent on the set average or sensitivity.
3) When calibrated in the application regularly.
4) The models with measuring range of 100 mm … 1,000 mm meets the specification of the models with measuring range of 100 mm … 1,000 mm for distances
< 600 mm.
5) 90% remission factor.
Technical drawings
Dimensional drawing
Connection type Male connector M12, 5-pin
Connection diagram
Adjustment possible